DUAL-ACTION ELECTRIC LOG SPLITTER
Troubleshooting Table (Continued)
SYMPTOM POSSIBLE CAUSE
Ram advances with a
jerky motion or with
strong vibrations.
Check the possible causes for the Ram operation symptom in “Log fails to split” above.
Check the hydraulic fluid level.
Bleed any accumulated air from the hydraulic system. To bleed, make sure the fluid level is
correct, cycle in one direction, bottom out, hold for 5 seconds, retract fully, bottom out, hold
for 5 seconds, repeat 10 times. If the problem persists, visit our website at
www.DRPower.com or call 1-800-DR-OWNER (376-9637) for assistance.
Hydraulic fluid leaking
from the ram or other
external parts.
The hydraulic fluid seals may be worn. Visit our website at www.DRPower.com or call 1-800-
DR-OWNER (376-9637), or call a qualified hydraulic mechanic for assistance to replace worn
components. Be sure to reference Hydraulic Safety in Chapter 1.
Splitter Breaker or house
Breaker is being tripped
excessively.
Pressure Valve set too high; Adjust Valve pressure by performing adjustment on page 18.
Before performing any repairs or maintenance procedure, unplug the Log Splitter power cord from the power source.